to mobile version

News

Alternative to the discontinued KTY84-130 Sensor

By discontinuation of KTY 84/83 NXP, the PTC-600 can be a conditional alternative under certain conditions.

Download PDF]

 

NXP KTY84-130
 
  • Temperature range: -40°C–300°C
  • R100 Resistance: 1000 Ohm
  • Tolerance @ 100°C: +-3%
  • Thermal time constant:
- Still air: 20s
- Still liquid: 1s
- Flowing liquid: 0,5s
  • Maximum sensor current(at 25°C): 10mA
  • Leads: nickel plated
PT1000
 
  • Temperature range: -200°C-400°C
  • R100 Resistance: 1385,055 Ohm
  • Tolerance @ 100°C: +-0,8%
  • Thermal time constant:
- Still air: 3,6s
- Still liquid: n.a
- Flowing liquid: 0,12s
  • Recommend sensor current (at 25°C): 0,3mA
  • Leads: silver plated

 PTC-600
 
  • Temperature range: -40°C–190°C
  • R100 Resistance: 1000 Ohm
  • Tolerance @ 100°C: +-3%
  • Thermal time constant:
- Still air: 21s
- Still liquid: n.a
- Flowing liquid: n.a
  • Maximum sensor current: 8mA
  • Leads: tinned dumet

 

By discontinuation of KTY 84/83 NXP, the PTC-600 can be a conditional alternative under certain conditions. Due to the technical and mechanical properties not for replace 100%.

Let us talk about which individual solution will be the best for you.

  • From about 160°C, the slope of the curve is no longer linear. (Disadvantage compared with KTY84)
  • Measuring range up to 190°C. (Disadvantage compared with KTY84)
  • The tinnes leads make the use of the sensor only up to 105°C. (Disadvantage compared with KTY84)
  • Singelsource. (Disadvantage)
  • Measuring current 2mA. (Corresponds KTY84)
  • The dimensions of the sensor deviates from the KTY sensor from: larger outer diameter, greather length, thicker wire.
  • The temperature sensor is independent of poliarity. (Advantage over KTY84)